lamaPLC Simatic

Simatic S7-1500 Siemens SIMATIC is one of the world's most widely used, highly reliable, modular automation systems. It is not affordable in terms of prices, it can be said to be damn expensive, but you have to pay for the quality.

The system has been on the market since the 80s, initially with a PLC family called the S5.

The S7 family was introduced in the early 2000s, with the 200, 300 and 400 PLC series and the programming interface now called Simatic Classic. This was replaced by the Simatic TIA Portal about 10 years ago, which integrated HMI (WinCC) in addition to programming solutions. At the same time, the 1200 and 1500 PLCs entered the market and can only be programmed with the TIA Portal.

Simatic can be programmed in several programming projecting languages, the so-called KOP / FUP (contact-plan, function-plan) for beginners. Programmers usually choose between AWL and SCL. AWL (Anweisungsliste / instruction list) is an ASSAMBY-like language, while SCL (Structured Control Language) is most similar to PASCAL.

On this site, I mainly deal with SCL, as I have been working with it for more than 10 years.

lamaPLC Simatic know-how contents

Simatic S7-1500 / S7-1200: Simatic S7-1500 / S7-1200
Simatic TIA portal (and classic) type-definitions: TIA Data-types
Simatic TIA SCL commands: SCL commands
Simatic TIA Basic know-hows: TIA Portal know-how
Simatic (TIA and classic) Modbus error- and statuscodes: Simatic Modbus S7 error- and statuscodes
Simatic S7 PLC types: S7 PLC types
Simatic TIA Diagnose generator: TIA Diagnose generator

2024/03/20 17:20

Simatic S7 Solutions

Metrawatt EM2389S7-1500 and Metrawatt EM2389 Modbus TCP communicationThe Metrawatt MID approved meters can be used to acquire and bill active energy in industrial, household, commercial and building management applications. The solution includes the downloadable S7 SCL source code and its description.

Last update: 18.05.2023
S7-1500 and Sicam Q200 Modbus TCP communicationS7-1500 and Sicam Q200 Modbus TCP communicationThe device measures voltages up to 480 V in 1-phase systems and in 3-wire and 4-wire systems (with neutral phase). The input circuits for voltage measurement can be used in IT, TT and TN networks. The solution includes the downloadable S7 SCL source code and its description.

Last update: 18.05.2023
UICPAL Temp.humi.sensorUICPAL Temp.humi.sensorThe relative humidity of air is the ratio of the absolute humidity in the air to the absolute humidity at saturation at the same temperature, which is a percentage. (that is, the percentage of the amount of water vapor in the air in a certain time and the amount of saturated water vapor at the temperature) is expressed by RH.

Last update: 17.06.2023