meta data for this page
  •  
Type of
measurement
ModelPower
voltage
Measurement, range, accuracyCommunicationNote
Airflow Sensor
Airflow Sensor
Nebulizer Air Switch
Unidro
6025/6027 6025/6027
3.3V
(2.5 .. 4.5V)
Output voltage: 3.7VAnalogLoad current: 5mA
Response time: 46ms
Temperature measuringHumidity measuring
Temperature
Humidity
Adafruit
AM2315C AM2315C
3.3 / 5 V
(2.2 .. 5.5V)
Temperature measurement range: -40 .. +80 °C
Temperature measurement accuracy: ±0.3°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2%
I²CMeasure: 3.2 mW
Reaction time: 8s
Temperature measuringAir-pressure measuring
Temperature
Air-pressure
Bosch
BMP180 BMP180
3.3 V
(1.62 .. 3.6V)
Temperature measurement range: -40 .. +85 °C
Temperature measurement accuracy: ±1.5°C
Air pressure Range: 4.35PSI .. 15.95PSI (30kPa .. 110kPa)
Air pressure accuracy: ±2%
I²C
default addr.: 0x77 (fix)
Maximum Pressure: 145.04PSI (1000kPa)
Temperature resolution: 0.1 °C
Pressure resolution: 1 Pa
Temperature measuringHumidity measuringAir-press measuring
Temperature
Humidity
Air pressure
Bosch
BME280 BME280
3.3 V
(1.71 .. 3.6V)
Temperature measurement range: -40 .. +80 °C
Temperature measurement accuracy: ±0.5°C (-40..85)
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±3%
Air pressure Range: 300 .. 1100 hPa
Air pressure accuracy: ±0.25%
I²C
default addr.: 0x76/77
SPI
-
Temperature measuringHumidity measuringAir-pressure measuring
Temperature
Humidity
Air pressure
Bosch
BME680 BME680
3.3 V
(1.71 .. 3.6V)
Temperature measurement range: -40 .. +80 °C
Temperature measurement accuracy: ±1.5°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±3%
Air pressure Range: 300 .. 1100 hPa
Air pressure accuracy: ±0.25%
I²C
default addr.: 0x76/77
SPI
Direct output of IAQ: Index for Air Quality
Temperature measuringAir-press measuring
Temperature
Air-pressure
Bosch
BMP280 BMP280
3.3 V
(1.71 .. 3.6V)
Temperature measurement range: -40 .. +85 °C
Temperature measurement accuracy: ±1.5°C
Air pressure Range: 4.35PSI .. 15.95PSI (30kPa .. 110kPa)
Air pressure accuracy: ±2%
I²C
default addr.: 0x76
SPI
Maximum Pressure: 290.08PSI (2000kPa)
Temperature resolution: 0.01 °C
Pressure resolution: 0.16 Pa
Gas sensor
CO2
VOC
Sciosense
CCS811 CCS811
3.3V
(1.8 .. 3.6V)
equivalent CO2 (eCO2): 400 ppm .. 32768 ppm
equivalent Total Volatile Organic Compound (eTVOC): 0 ppb .. 29206 ppb.
I²C
default address: 0x5A / 0x5B
Standard (100kbit/s) and fast (400kbit/s) I²C interface
Power Consumption maximum: 46 mW
Temperature sensor
Non-Contact Thermal Sensor
Omron
D6T-32L D6T-32L
5VNumber of elements: 1024 (32 × 32)
Current consumption: 19 mA
Object temperature detection:
D6T-32L-01A: 0 to 200°C
I²CResponse time: 200 msec
Arduino lib
Temperature sensor
Non-Contact Thermal Sensor
Omron
D6T-44L D6T-44L
5VNumber of elements: 16 (4 × 4)
Current consumption: 5 mA
Object temperature detection:
D6T-44L-06: 5 .. 50°C
D6T-44L-06H: 5 .. 200°C
I²CResponse time: 300 msec
Arduino lib
Temperature sensor
Non-Contact Thermal Sensor
Omron
D6T-8L D6T-8L
5VNumber of elements: 8 (1 × 8)
Current consumption: 5 mA
Object temperature detection:
D6T-8L-09: 5 .. 50°C
D6T-8L-09H: 5 .. 200°C
I²CResponse time: 250 msec
Arduino lib
Temperature sensor
Non-Contact Thermal Sensor
Omron
D6T-1A D6T-1A
5VNumber of elements: 1 (1 × 1)
Current consumption: 3.5 mA
Object temperature detection:
D6T-1A-01: 5 .. 50°C
D6T-1A-02: -40 .. 80°C
I²CResponse time: 100 msec
Arduino lib
Temperature measuringHumidity measuring
Temperature
Humidity
DHT11 DHT113.3 / 5 V
(3.3 .. 5.5V)
Temperature measurement range: 0 .. +50 °C
Temperature measurement accuracy: ±2°C
Humidity measurement range: 20..90% RH
Humidity measurement accuracy: ±5%
1-Wire8 bit resolution, response time 10 sec
Temperature measuringHumidity measuring
Temperature
Humidity
DHT20 DHT203.3 / 5 V
(2.2 .. 5.5V)
Temperature measurement range: -40 .. +80 °C
Temperature measurement accuracy: ±0.5°C (-40..80)
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±3%
I²C
default addr.: 0x38
-
Temperature measuringHumidity measuring
Temperature
Humidity
DHT22
AM2302
DHT22
3.3 / 5 V
(2.2 .. 5.5V)
Temperature measurement range: -40 .. +80 °C
Temperature measurement accuracy: ±0.5°C (-40..80)
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2%
single-bus-
Temperature sensorPressure sensor
Barometric Pressure Sensor
Infineon
DPS310 DPS310
3.3VSupply voltage: VDDIO: 1.2 .. 3.6 V
Operation range: Pressure: 300 .. 1200 hPa. Temperature: -40 – 85 °C
Pressure sensor precision: ± 0.002 hPa (or ±0.02 m) (high precision mode)
Relative accuracy: ± 0.06 hPa (or ±0.5 m)
Absolute accuracy: ± 1 hPa (or ±8 m)
Temperature accuracy: ± 0.5°C
Pressure temperature sensitivity: 0.5Pa/K
I²C or SPI
I2C default address: 0x76 (SDO←GND) or 0x77 (SDO←VDDIO)
Measurement time: Typical: 27.6 ms
Temperature measuring
Temperature
Dallas
DS18B20 DS18B20
3.3 / 5 V
(3.3 .. 5.5V)
Temperature measurement range: -55 .. +125 °C
Temperature measurement accuracy: ±0.5°C
1-Wire9 to 12 bit (selectable) resolution
Conversion Time < 750ms
Current Consumption: 1mA
Gas sensor
NO²
MEMS
GM-102b GM-102
5VDetection Range: 0.1~10ppm (NO²)
Heater Resistance: 80Ω±20Ω(room temperature
analog signal-
Gas sensor
alcohol gas
MEMS
GM-302b GM-302
5VDetection Range: 1..500ppm (Ethanol vapor)
80Ω±20Ω(room temperature
analog signal-
Gas sensor
Alcohol (C2H5OH)
Hydrogen(H2)
Formaldehyde(CH2O)
MEMS
GM-502b GM-502
5VDetection: Alcohol (C2H5OH), 10..500ppm
Detection: Hydrogen(H2), 1..1000ppm
Detection: Formaldehyde(CH2O), 10..100ppm
analog signal-
Gas sensor
Carbon monoxide (CO)
Hydrogen (H2)
MEMS
GM-702b GM-702
5VDetection:
Carbon monoxide sensor (CO) : 10..5000ppm
Hydrogen sensor (H2): 10..500ppm
analog signal-
Temperature measuringHumidity measuring
Temperature
Humidity
Texas Instruments
HDC 1080 HDC 1080
3.3 - 5 V
(2.7 .. 5.5V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.2°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2%
I²C
default addr.: 0x40
14 Bit Measurement Resolution
100 nA Sleep Mode Current
Temperature measuringHumidity measuring
Temperature
Humidity
TE Connectivity
HTU21 HTU21
3.3V
(1.5 .. 3.6V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.3°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2%
I²C
default addr.: 0x40 (fix)
Power Dissipation: 2.7 µW
Resolution: 12 / 8 bit
Measuring Time: 3..16 ms
Gas sensor
Carbon monoxide (CO)
Methane (CH4)
Ethanol (C2H5OH)
Propane (C3H8)
Butane (C4H10)
Hydrogen (H2)
Hydrogen sulfide (H2S)
Ammonia (NH3)
Fermion
MICS-5524 V1.0 MICS-5524 V1.0
5VThe module is intended for educational and hobby purposes!

Measuring range:
1 .. 1000 ppm (carbon monoxide CO)
10 .. 500ppm (Ethanol C2H5OH)
1 .. 1000ppm (Hydrogen H2)
1 .. 500 ppm (NH3 ammonia)
> 1000 ppm (methane CH4)
analog signal-
Gas sensor
Smoke gas
Combustible gas
Winsen
MQ-2 MQ-2
5VFlammable gas concentracion: 300 .. 10'000ppm

Heater Resistance; RH: 29Ω ±3Ω(room tem.)
Heater consumption; PH: ≤950mW
Sensitivity;S: Ro(in air) / Rs (2000 ppm C3H8) ≥ 5
Output Voltage;Vs: 2.5V~4.0V(in 2000 ppm C3H8
Concentration Slope;α: ≤0.6 (R3000 ppm / R1000 ppm C3H8)
analog signalLifespan: 10 years
Preheat time: Over 24 hour
Gas sensor
Alcohol gas

Small sensitivy: Benzine gas
Winsen
MQ-3 MQ-3
5VDetecting concentration scope:0.05 mg / 10 mg/L Alcohol

Sensing Resistance: 1 MΩ - 8 MΩ (0.4 mg/L alcohol)
analog signalPreheat time: Over 24 hour
Gas sensor
CH4 gas
Natural gas
LNG


Small sensitivy:
Alcohol
Smoke
Winsen
MQ-4 MQ-4
5VDetecting concentration scope:200-10'000ppm CH4, natural gas

Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
analog signalPreheat time: Over 24 hour
Gas sensor
LPG
Iso-butane
Propane


Small sensitivy:
Alcohol
Smoke
Winsen
MQ-5 MQ-5
5VDetecting concentration scope:200-10'000ppm LPG,LNG, Natural gas, Iso-butane, Propane, Town gas

Sensing Resistance: 10KΩ- 60KΩ (5000 ppm methane)
analog signalPreheat time: Over 24 hour
Gas sensor
Town gas
Natural gas
LPG
LNG
Iso-butane
Propane


Small sensitivy:
Alcohol
Smoke
Winsen
MQ-6 MQ-6
5VDetecting concentration scope:200-10'000ppm LPG ,iso-butane, propane, LNG

Sensing Resistance: 10KΩ- 60KΩ (10'00ppm LPG)
analog signalPreheat time: Over 24 hour
Gas sensor
CO
Winsen
MQ-7 MQ-7
5VDetecting concentration scope:over 300 ppm CO (Carbon Monoxide)

Sensing Resistance: 2KΩ- 20KΩ (100 ppm CO)
analog signalPreheat time: Over 48 hour
Gas sensor
H2

Small sensitivy:
Alcohol
LPG
cooking fumes
Winsen
MQ-8 MQ-8
5VDetecting concentration scope:100-10000ppm Hydrogen (H2)

Sensing Resistance: 10KΩ- 60KΩ (1000 ppm H2)
analog signalPreheat time: Over 24 hour
Gas sensor
CO
CH4 gas
LPG
Winsen
MQ-9 MQ-9
5VDetecting range:
20 ppm .. 2000 ppm carbon monoxide
500 ppm .. 10'000 ppm CH4
500 ppm .. 10'000 ppm LPG

Sensing Resistance: 2KΩ- 20KΩ (100 ppm CH4)
analog signalPreheat time: Over 48 hour
Gas sensor
NOx
NH3
alcohol
Benzene
smoke
CO2
Winsen
MQ-135 MQ-135
5VDetecting range:
10 ppm .. 300 ppm NH3
10 ppm .. 1000 ppm Benzene
10 ppm .. 300 ppm Alcohol

Sensing Resistance: 30KΩ- 200KΩ (100 ppm NH3)
analog signalPreheat time: Over 24 hour
Gas sensor
Oxigen
AlphaSense
O2-A2 O2-A2
5VRange of oxygen sensor: 0..30 %
Load resistance: 47-100 Ω
analog signal-
Gas sensorTemperature sensorHumidity sensor
CO2
humidity
temperature
SCD-30 SCD-303.3V / 5VHumidity range: 0 .. 100 %RH
Temperature range: -40°C .. 70°C
CO² range: 0 .. 40’000 ppm (I²C, UART), 0 .. 5’000 ppm (PWM)
UART (Modbus Point to Point; TTL Logic), PWM and I²CResponse time: 20s
Sensor lifetime: 15 years
Gas sensorTemperature measuringHumidity measuring
CO2
Air-quality
Temperature
Humidity
Sensirion
SCD40-D-R2 SCD40-D-R2
3.3V / 5V
(2.4 .. 5.5V)
CO2 output range: 0 .. 40'000 ppm
CO2 measurement accuracy: ± 40 ppm
Humidity measurement range: 0 %RH .. 100 %RH
Humidity measurement accuracy: ±6 %RH
Temperature measurement range: 10°C .. 60°C
Temperature measurement accuracy: ±1.5 °C
I²C
default address: 0x62
SCL clock frequency: 100 kHz
Gas quality
VOC -
CO2-eq Sensor
Sensirion
SGP30 SGP30
1.8VSupply voltage 1.62 .. 1.98 V
Measurement range (CO₂-eq): 0 .. 1000 ppm
Specified range:
Ethanol signal: 0.3 ppm .. 30 ppm
H2 signal 0.5 ppm .. 3 ppm
I²C
I2C default address: 0x58
Sampling frequency: Max. 40 Hz
Data sheet
Gas quality
Indoor Air Quality Sensor for VOC Measurements
Sensirion
SGP40 SGP40
3.3VSupply voltage 1.7 .. 3.6 V
Ethanol in clean air: 0 .. 1000 ppm
I²C
I2C default address: 0x59
Sampling frequency: Max. 40 Hz
Data sheet
Gas quality
Air Quality Sensor for VOC and NOx Measurements
Sensirion
SGP41 SGP41
3.3VSupply voltage 1.7 .. 3.6 V
Ethanol in clean air: 0 .. 1.000.000 ppm
NO2 in clean air: 0 .. 10.000 ppm
I²C
I2C default address: 0x59
Sampling frequency: Max. 40 Hz
Data sheet
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT20 SHT20
3.3V
(2.1 .. 3.6V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.3°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy:±3%
I²C
default addr.: 0x40/41
3.2 µW (at 8 bits, 1 measurement /s)
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT21 SHT21
3.3V
(2.1 .. 3.6V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.3°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2%
I²C
default addr.: 0x40/41
3.2 µW (at 8 bits, 1 measurement /s)
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT25 SHT25
3.3V
(2.1 .. 3.6V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.2°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±1.8%
I²C
default addr.: 0x40/41
3.2 µW (at 8 bits, 1 measurement /s)
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT30 SHT30
3.3 / 5 V
(2.15 .. 5.5V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.2°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2% (10..90%)
I²C
default addr.: 0x44/45
4.8 µW (1 measurement/s)
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT31 SHT31
3.3 / 5 V
(2.15 .. 5.5V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.2°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2% (0..100%)
I²C
default addr.: 0x44/45
4.8 µW (1 measurement/s)
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT35 SHT35
3.3 / 5 V
(2.15 .. 5.5V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.2°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±1.5% (0..80%)
I²C
default addr.: 0x44/45
4.8 µW (1 measurement/s)
Temperature measuringHumidity measuring
Temperature
Humidity
Sensirion
SHT40 SHT40
3.3
(1.08 .. 3.6V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.2°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±1.8%
I²C
default addr.: 0x44/45
4.0 µW (1 measurement/s)
Temperature measuringHumidity measuring
Temperature
Humidity
Siliconlabs
Si-7021 Si-7021
3.3V
(1.9 .. 3.6V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.3°C
Humidity measurement range: 0..100% RH
Humidity measurement accuracy: ±2%
I²C
default addr.: 0x40
-
Temperature measuring
Temperature
Microchip
TC1047A TC1047A
5 / 3.3V
(2.5 .. 5.5V)
Temperature measurement range: -40 .. +125 °C
Temperature measurement accuracy: ±0.5°C
analog
10mV/°C
Maximum Supply Current 60uA
Gas sensor
Methane
Natural gas
GL Sciences
TGS-2611 TGS-2611
5VSensor resistance in 5000ppm of methaneat 20°C and 65% R.H.
Sensor resistance: 0.68 .. 6.8 kΩ in 5000 ppm methane
analog signalConditioning period before test: 7 days