lamaPLC: DM56A04 / DM36B06 digital tube display with Modbus Communication

Description

  • Working voltage: DC 5~28V
  • Working current: 4.3~42mA (related to the brightness of the digital tube)
  • MODBUS RTU protocol, 03 read command, 06 or 16 write command.
  • Device address: 1~247, default 1, by modifying the 485 address, up to 247 modules can be used in cascade (more than 32, please use RS485 repeater)
  • Digital tube color: red
  • Digital tube tube digits: 6 digits 0.36 inches / 4 digits 0.56 inches
  • Communication interface: RS-485
  • Function: It can display numbers, ASCII characters, letters, floating-point numbers, negative numbers, etc., and the brightness can be adjusted; it supports electronic label function, and the initial display content can be set after power-on
  • Supported baud rates: 1200 2400 4800 9600 (default) 19200 38400 57600 115200

Modbus Features

Modbus connection characteristics:
Default Modbus settings: 9600 baud, 8N1, RTU communication, slave ID: 1

AddressFunction
0To display Data send
1Position of the decimal Point
2Set Brightness
3Set flash
4Set Baudrate (Range 0 – 7 corresponds to 0:1200 1:2400 2:4800 3:9600 4:19200 5:38400 6:57600 7:115200)
5Set the Address