| + | The original S7 series debuted in the mid-1990s as a successor to the S5 line. The current generation (S7) was introduced between 2009 and 2013 to integrate with the TIA Portal. | ||
| + | |||
| Siemens SIMATIC S7 controllers range from compact, entry-level units to high-performance modular systems designed for complex industrial automation. The S7-1200 and S7-1500 represent the current generation optimized for the TIA Portal, while the S7-300 and S7-400 are legacy modular systems. | Siemens SIMATIC S7 controllers range from compact, entry-level units to high-performance modular systems designed for complex industrial automation. The S7-1200 and S7-1500 represent the current generation optimized for the TIA Portal, while the S7-300 and S7-400 are legacy modular systems. | ||
| + | |||
| + | |||
| ^Feature^LOGO! (Basic)^S7-1200 (Compact)^S7-1500 (Advanced)^S7-300 (Legacy)^S7-400 (High-End)| | ^Feature^LOGO! (Basic)^S7-1200 (Compact)^S7-1500 (Advanced)^S7-300 (Legacy)^S7-400 (High-End)| | ||
| - | ^Design Programmable Relay|Compact Modular|Modular with Display|Modular Large Modular| | + | |-|{{: |
| + | ^Launch Year|1996|2009|2012|1994|1994| | ||
| + | ^Status|Active (Current: LOGO! 8)|Active (G2 launched Dec 2024)|Active (Flagship series)|// | ||
| + | ^Design|Logic Module \\ Programmable Relay|Compact Modular|Modular with Display|Legacy | ||
| ^Max Digital I/O|24 Inputs / 20 Outputs|Up to ~280|High Density (thousands)|High Density|Very High (rack-based)| | ^Max Digital I/O|24 Inputs / 20 Outputs|Up to ~280|High Density (thousands)|High Density|Very High (rack-based)| | ||
| - | ^Integrated I/O|Always included|Integrated onboard|No (onboard display only)|Some models only|No|| | + | ^Integrated I/O|Always included|Integrated onboard|No (onboard display only)|Some models only|No| |
| ^Expansion|35mm DIN rail modules|Max 8 Signal Modules|Max 32 modules/ | ^Expansion|35mm DIN rail modules|Max 8 Signal Modules|Max 32 modules/ | ||
| ^Redundancy|No|No|Hardware (R/H models)|Software only|Full Hardware (H)| | ^Redundancy|No|No|Hardware (R/H models)|Software only|Full Hardware (H)| | ||
| ^Software|LOGO! Soft Comfort|TIA Portal|TIA Portal|Step 7 / TIA Portal|Step 7 / TIA Portal| | ^Software|LOGO! Soft Comfort|TIA Portal|TIA Portal|Step 7 / TIA Portal|Step 7 / TIA Portal| | ||