lamaPLC: TM1650 7-Segment Display with Modbus Communication

TM1650 7-Segment Display with Modbus Communication

The TM1650 / STC8G IC performs the module's 7-segment control, and the TP8485E IC provides the Modbus communication connection.

This display is a 4-digit 7-segment display with a decimal point.

TM1650 7-Segment Display with Modbus CommunicationTM1650 7-Segment Display with Modbus CommunicationTM1650 7-Segment Display with Modbus Communication

Modbus Features

Modbus connection characteristics:
Default Modbus settings: 9600 baud, 8N1, RTU communication, slave ID: 1

After powering up, a number, such as “0013”, flashes briefly. The first digit represents the slave ID (1), and the second indicates the baud rate (3: 9600).

The “write multiple registers” Modbus function (10) works, with three information (signal, number of digits, brightness) (2.468 / low brightness 1: TX 01 10 00 00 00 03 06 09 a4 00 03 00 01 a6 00)

The registers must be written one at a time using the “write single register” function (6). (Send 1234: TX: 01 06 00 00 04 d2 0b 57)

AddressFunction
0To display Data send
1Position of the decimal Point
2Set Brightness
3Set flash
4Set Baudrate (Range 0 – 7 corresponds to 0:1200 1:2400 2:4800 3:9600 4:19200 5:38400 6:57600 7:115200)
5Set the Address