Click on the column header to rearrange!
Type of measurement | Model | Power voltage | Measurement, range, accuracy | Communication | Note |
---|---|---|---|---|---|
CO2 VOC | Sciosense CCS811 | 3.3V (1.8 .. 3.6V) | equivalent CO2 (eCO2): 400 ppm .. 32768 ppm equivalent Total Volatile Organic Compound (eTVOC): 0 ppb .. 29206 ppb. | I²C default address: 0x5A / 0x5B | Standard (100kbit/s) and fast (400kbit/s) I²C interface Power Consumption maximum: 46 mW |
CO2 Air-quality Temperature Humidity | Sensirion SCD40-D-R2 | 3.3V / 5V (2.4 .. 5.5V) | CO2 output range: 0 .. 40'000 ppm CO2 measurement accuracy: ± 40 ppm Humidity measurement range: 0 %RH .. 100 %RH Humidity measurement accuracy: ±6 %RH Temperature measurement range: 10°C .. 60°C Temperature measurement accuracy: ±1.5 °C | I²C default address: 0x62 | SCL clock frequency: 100 kHz |
Smoke gas Combustible gas | Winsen MQ-2 | 5V | Flammable gas concentracion: 300 .. 10'000ppm Heater Resistance; RH: 29Ω ±3Ω(room tem.) Heater consumption; PH: ≤950mW Sensitivity;S: Ro(in air) / Rs (2000 ppm C3H8) ≥ 5 Output Voltage;Vs: 2.5V~4.0V(in 2000 ppm C3H8) Concentration Slope;α: ≤0.6 (R3000 ppm / R1000 ppm C3H8) | analog signal | Lifespan: 10 years Preheat time: Over 24 hour |
Alcohol gas Small sensitivy: Benzine gas | Winsen MQ-3 | 5V | Detecting concentration scope:0.05 mg / 10 mg/L Alcohol Sensing Resistance: 1 MΩ - 8 MΩ (0.4 mg/L alcohol) | analog signal | Preheat time: Over 24 hour |
CH4 gas Natural gas LNG Small sensitivy: Alcohol Smoke | Winsen MQ-4 | 5V | Detecting concentration scope:200-10'000ppm CH4, natural gas Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4) | analog signal | Preheat time: Over 24 hour |
LPG Iso-butane Propane Small sensitivy: Alcohol Smoke | Winsen MQ-5 | 5V | Detecting concentration scope:200-10'000ppm LPG,LNG, Natural gas, Iso-butane, Propane, Town gas Sensing Resistance: 10KΩ- 60KΩ (5000 ppm methane) | analog signal | Preheat time: Over 24 hour |
Town gas Natural gas LPG LNG Iso-butane Propane Small sensitivy: Alcohol Smoke | Winsen MQ-6 | 5V | Detecting concentration scope:200-10'000ppm LPG ,iso-butane, propane, LNG Sensing Resistance: 10KΩ- 60KΩ (10'00ppm LPG) | analog signal | Preheat time: Over 24 hour |
CO | Winsen MQ-7 | 5V | Detecting concentration scope:over 300 ppm CO (Carbon Monoxide) Sensing Resistance: 2KΩ- 20KΩ (100 ppm CO) | analog signal | Preheat time: Over 48 hour |
H2 Small sensitivy: Alcohol LPG cooking fumes | Winsen MQ-8 | 5V | Detecting concentration scope:100-10000ppm Hydrogen (H2) Sensing Resistance: 10KΩ- 60KΩ (1000 ppm H2) | analog signal | Preheat time: Over 24 hour |
CO CH4 gas LPG | Winsen MQ-9 | 5V | Detecting range: 20 ppm .. 2000 ppm carbon monoxide 500 ppm .. 10'000 ppm CH4 500 ppm .. 10'000 ppm LPG Sensing Resistance: 2KΩ- 20KΩ (100 ppm CH4) | analog signal | Preheat time: Over 48 hour |
NOx NH3 alcohol Benzene smoke CO2 | Winsen MQ-135 | 5V | Detecting range: 10 ppm .. 300 ppm NH3 10 ppm .. 1000 ppm Benzene 10 ppm .. 300 ppm Alcohol Sensing Resistance: 30KΩ- 200KΩ (100 ppm NH3) | analog signal | Preheat time: Over 24 hour |
Oxigen | AlphaSense O2-A2 | 5V | Range of oxygen sensor: 0..30 % Load resistance: 47-100 Ω | analog signal | - |
Methane Natural gas | GL Sciences TGS-2611 | 5V | Sensor resistance in 5000ppm of methaneat 20°C and 65% R.H. Sensor resistance: 0.68 .. 6.8 kΩ in 5000 ppm methane | analog signal | Conditioning period before test: 7 days |
CO2 humidity temperature | Sensirion SCD-30 | 3.3V / 5V | Humidity range: 0 .. 100 %RH Temperature range: -40°C .. 70°C CO² range: 0 .. 40’000 ppm (I²C, UART), 0 .. 5’000 ppm (PWM) | UART (Modbus Point to Point; TTL Logic), PWM and I²C | Response time: 20s Sensor lifetime: 15 years |
NO² | MEMS GM-102b | 5V | Detection Range: 0.1~10ppm (NO²) Heater Resistance: 80Ω±20Ω(room temperature | analog signal | - |
alcohol gas | MEMS GM-302b | 5V | Detection Range: 1..500ppm (Ethanol vapor) 80Ω±20Ω(room temperature | analog signal | - |
Alcohol (C2H5OH) Hydrogen(H2) Formaldehyde(CH2O) | MEMS GM-502b | 5V | Detection: Alcohol (C2H5OH), 10..500ppm Detection: Hydrogen(H2), 1..1000ppm Detection: Formaldehyde(CH2O), 10..100ppm | analog signal | - |
Carbon monoxide (CO) Hydrogen (H2) | MEMS GM-702b | 5V | Detection: Carbon monoxide sensor (CO) : 10..5000ppm Hydrogen sensor (H2): 10..500ppm | analog signal | - |
Carbon monoxide (CO) Methane (CH4) Ethanol (C2H5OH) Propane (C3H8) Butane (C4H10) Hydrogen (H2) Hydrogen sulfide (H2S) Ammonia (NH3) | Fermion MICS-5524 V1.0 | 5V | The module is intended for educational and hobby purposes! Measuring range: 1 .. 1000 ppm (carbon monoxide CO) 10 .. 500ppm (Ethanol C2H5OH) 1 .. 1000ppm (Hydrogen H2) 1 .. 500 ppm (NH3 ammonia) > 1000 ppm (methane CH4) | analog signal | - |