Modbus connection characteristics:
Default Modbus settings: 9600 baud, 8N1, RTU communication, slave ID: 1
Function Code: 06/16 control, 03 read status
| Address | Function | R/W |
|---|---|---|
| 0 | ASCII code The 1st digit tube displays the contents | R/W |
| 1 | ASCII code The 2nd digit tube displays the contents | R/W |
| 2 | ASCII code The 3st digit tube displays the contents | R/W |
| 3 | ASCII code The 4st digit tube displays the contents | R/W |
| 4 | ASCII code The 5st digit tube displays the contents | R/W |
| 5 | ASCII code The 6st digit tube displays the contents | R/W |
| 6 | Used in combination with register 7 (0xFFFFFFFF), cannot be used alone. High 4 bits of the high byte (0xFFFFFFFF): 0 indicates a positive number, 1 indicates a negative number Lower 4 bits of the high byte (0xFFFFFFFF): specify the number of decimal places, ranging from 0 to 5 Together with register 7, they specify the data to be displayed 0xFFFFFFFF) (for data above 65535, three bytes are needed; this byte indicates the highest 8 bits of the data. Note: This register should be used together with register 7. To write data to these two registers, use the write multiple holding register (16 function code) when displaying data. | R/W |
| 7 | Display data. Can be used in combination with register 6 (0xFFFFFFFF), or separately. (1) Together with register 6, this register indicates the data to be displayed (the data is represented by 3 bytes, 0xFFFFFFFF), the high byte of this register indicates the middle 8 bits of the data (0xFFFFFF), and the low byte indicates the lowest 8 bits of the data (0xFFFFFF). The high byte comes first and the low byte comes second. (0xFFFF) Note: This register is used in conjunction with register 6 to write data to these two registers using the Write Multiple Holding Register (16 function code) when displaying data. (2) When used independently, write a hexadecimal number into the register, and the digital tube will be converted into a decimal number for display. | R/W |
| 8 | Blink control register. Each bit represents one digital tube; the lowest bit represents the first digital tube, and so on. 0: no blinking (default), 1: Blinking Note: This parameter is not saved when power is lost. | R/W |
| 9 | Digital tube brightness level, 1..8, 6 digits default 4, 4 digits default 8. Note: This parameter is saved upon powering down. | R/W |
| 10 | Display content is saved. 0: No saving (default), 1: Save all digital tube display content Note: this parameter is saved when powered off. | R/W |
| 11 | Digital tube power-on initial display mode setting. 0: Display “0”; (default), 1: Display the RS485 address of the module, 2: Display of saved data. Note: This parameter is saved at power down. | R/W |
| 251 | 00: Restore factory settings Telegram: FF 06 00 FB 00 00 ED E5 | R/W |
| 252 | Data return delay: 0..25 (* 40 ms); Return data interval time after receiving the command (unit 40 ms) | R/W |
| 253 | RS485 Address / Slave Address: 1..247, default: 1 | R/W |
| 254 | Baud rate: 0..255; 0:1200, 1:2400 2:4800, 3:9600(default), 4:19200, 5:38400, 6:57600, 7:115200, Other: Restore factory settings | R/W |
| 255 | Parity bit: 0..2; 0 :None(default), 1: Even Parity, 2: Odd Parity | R/W |